Horizontal Fiber Optic Splice Closure (FOSC) GJS-X
1. Scope of application
This Installation Manual suits for the Fiber Optic Splice Closure (Hereafter abbreviated as FOSC), as the guidance of proper installation.
The scope of application is: aerial and wall-mounting. The ambient temperature ranges from -40 to 60℃.
2. Basic structure and configuration
2.1 Dimension and capacity
Outside dimension (LengthxHeightxWidth) |
205mm*45mm*210 mm |
Weight (excluding outside box) |
1000g |
Number of inlet/outlet ports |
4 pieces in general |
Diameter of fiber cable |
Φ6mm—Φ18 mm |
Capacity of FOSC |
Bunchy: 1—32 (Cores) |
2.2 Main components
No. |
Name of components |
Quantity |
Usage |
Remarks |
1 |
FOSC cover |
1 piece |
Protecting fiber cable splices in whole |
LengthxHeightxWidth 205mm*45mm*210 mm |
2 |
Fiber optic splice tray (FOST) |
max. 1 pieces (bunchy) |
Fixing heat shrinkable protective sleeve and holding fibers |
Suitable for: Bunchy:4,6,8(cores) |
3 |
Base |
1 set |
Fixing internal and external structure |
|
4 |
Screw |
4 set |
Fixing between FOSC cover and FOSC base |
|
5 |
Seal fitting |
1 piece |
Sealing between FOSC cover and FOSC base |
|
2.3 Main accessories and special tools
No. |
Name of accessories |
Quantity |
Usage |
Remarks |
1 |
Heat shrinkable protective sleeve |
12 piece |
Protecting fiber splices |
|
2 |
Nylon tie |
|
Fixing fiber with protective coat |
|
3 |
Installation tape |
1 roll |
Enlarging diameter of fiber cable for easy fixing |
|
4 |
Seal tape |
1 roll |
Enlarging diameter of fiber cable which fits in with seal fitting |
|
5 |
Dry agent |
1 bag |
Put into FOSC before sealing for desiccating air |
|
6 |
Special wrench |
1 piece |
Fixing octagonal nut |
|
7 |
Labeling paper |
1 piece |
Labeling fibers |
|
3. Necessary tools for installation
3.1 Supplementary materials (to be provided by operator)
Name of materials |
Usage |
Scotch tape |
Labeling, temporarily fixing |
Ethyl alcohol |
Cleaning |
Gauze |
Cleaning |
3.2 Special tools (to be provided by operator)
Name of tools |
Usage |
Fiber cutter |
Cutting off fibers cable |
Fiber stripper |
Strip off protective coat of fiber cable |
Combo tools |
Assembling FOSC |
3.3 Universal tools (to be provided by operator)
Name of tools |
Usage and specification |
Band tape |
Measuring fiber cable |
Pipe cutter |
Cutting fiber cable |
Electrical cutter |
Take off protective coat of fiber cable |
Combination pliers |
Cutting off reinforced core |
Screwdriver |
Crossing/Paralleling screwdriver |
Scissor |
Cutting off reinforced yarns |
Waterproof cover |
Waterproof, dustproof |
Metal wrench |
Tightening nut of reinforced core |
3.4 Splicing and testing instruments (to be provided by operator)
Name of instruments |
Usage and specification |
Fusion Splicing Machine |
Fiber splicing |
OT DR |
Splicing testing |
Provisional splicing tools |
Provisional testing |
Fire sprayer |
Sealing heat shrinkable fixing sleeve |
Notice: The above-mentioned tools and testing instruments should be provided by the operators themselves.
4. Installation flow chart
1. Open the closure
2. Determine length of fiber cable to be fixed and stripped inside FOSC
3. Strip off protective coats of fiber cable and fiber
4. Separate fiber cores and prepare work prior to fixing fiber cable
5. Fix reinforced core and fiber cable
6. Splice fibers
7. Install heat shrinkable protective sleeve and house fibers
8. Check up comprehensively
9. Assemble FOSC housing and fixing FOSC
5. The process of installing FOSC
5.1 Step One - Open the closure
5.1.1 Cleaning the locale and determine where to install the FOSC and then place
fiber cables required.
5.1.2 Check whether the main components and accessories have been well prepared
inside the package.
5.1.3 Open the closure
①Use the special wrench to demount all the locating bolts on the housing as well as fixing bolts at four corners and then succeed in opening closure.
② Pull the FOSC cover upwards out .installation could begin.
5.1.4 See Drawing 1
Important issues: If the weather condition is not good enough, then a tent must be pitched
for waterproof and dustproof.
5.2 Step Two -Determine length of fiber cable to be fixed and stripped inside FOSC
5.2.1 Please refer to Drawing 2 for stripping length.
①. Fiber cable in 60mm length: the distance from seal fitting to fiber cable pressboard
②. Fiber cable in 1950mm length: it is used to be winded and spliced after stripping.
③. Fiber with protective coat in 1350mm length: the distance from the fixing point of fiber cable to the fixing point of FOST (fiber optic splice tray).
④. Fiber in 1600mm length: after stripping off the protective coat, it is to be winded inside the FOST after splicing with other fibers
5.2.2 See Drawing 2
1. Reserve enough length of fiber cable to be spliced.
2. Stripping length also could be decided by customer according to installation requirement.
5.3 Step Three – Strip off fiber protective coat of fiber cable and fiber
5.3.1 Strip off protective coat of fiber cable from the temp. locating mark with the cutter and the
stripper, please refer to Drawing 2 for stripping length. Stripping length also could be
decided according to installation requirement
5.3.2 See Drawing 3.
Important issues: If it is difficult to strip off all the protective coat of fiber cable at one time,
strip it off section by section to avoid fiber breakage.
5.4 Step Four – Separate fiber cores and prepare work prior to fixing fiber cable.
5.4.1 Wind 2 layers of insulation tape on protective coat of fiber core for protection. Meanwhile, get rid of the stuffing to separate fiber and clean them. Form a ring with the diameter of 100mm or so and fix it on the fiber temporarily by adhesive tape.
5.4.2 FOSC-X is provided with 4 inlet/outlet ports ,the inlet/outlet ports cloud be decided to according to diameter of fiber cables to be actully installed .then the corresponding number of ports plugs should be take out.
5.4.3 This FOSC is stuitable for the following diameters of fiber cables respectivly
Port A :stuitable for fiber cable with max :diameter 18MM
Port B :stuitable for fiber cable with max :diameter 6MM
5.4.4 The corresponding inlet/outlet ports are to be selected according to fiber cables actully installed .when the diameter of fiber cable is smaller then that of the inlet/outlet ports .then the seal tape shuold be used enlarge the diameter of fiber cable.of which the perimeter could be measured by the corresponding measuring paper.
5.4.5 Reserve reinforced core in 35mm length and cut off the unnecessary ones.
5.4.6 See Drawing 4
Important Issues: 1.Before the seal tape is used for enlarging the fiber cable diameter,it shuold be scratched and to be cleaned with abrasive cloth ethyl alcohol.
2.Cut off reinforced core with a special cutting plier.
5.5 Step Five - Fix reinforced core and fiber cable
5.5.1 UP finishing the above steps ,then demount port plugs,pressboard and fixing out of reinforced core.Make sure whether the fiber cable stripped fits in with the fixing ports or not.if not adjustment should be done in time .Otherwise it will affect installation quality.
5.5.2 tighten fiber cable pressboart.diameter of fiber cable is small.then enlarge it with insulation tape.
5.5.3 tighten out of reinforced core with the special wrench (plastic) and then retighten it with metal wrench(the metal wrench shuold be provided operator)
5.5.4 See Drawing 5
Important Issues: 1.fixing out of einforced core should be tightened
2.while heating.heat shrinkable fix tube shuold shrik evenly .and there should be no bubbles .pores and other defects inside the tube.
5.6 Step Six - Splice fibers
5.6.1 Follow user manual of fusion splicing machine to splice fiber.
Important issue: pay attention to the twist and bend of fiber.
5.7 Step Seven -Install heat shrinkable protective sleeve and house fibers
5.7.1 When having completed splicing the fibers, the first fiber ring should be housed on the farthest side of FOST, the remaining fiber should be winded, forming a ring with diameter not less than 80mm. then put it into FOST (Fiber Optic Splice Tray) together with heat shrinkable protective sleeve.( Firstly fix heat shrinkable protective sleeve into the slot, then enlarge the diameter of fiber ring properly.)
Important issue :pay attention to the twist and bend of fiber.
5.8 Step Eight - Check up comprehensively
To ensure the technical requirements, the following instructions must be followed:
5.8.1 The fibers in the FOST are spliced and installed orderly. The curved diameter of fiber meets with the technical requirements.
5.8.2 The inlet/outlet ports without fiber cables installed must be blocked up with the port plugs.
5.8.3 Fibers with protective coat are fixed with nylon ta the entrance of FOST.
5.8.4 The inlet/outlet ports without fiber cables installed must be blocked up with the port plugs.
5.8.5Control the amount of seal tape within a proper range.
5.8.6 Seal fitting is installed neatly and smoothly. If not, level it up with seal tape.
Important issue : If any problems occur, they should be solved right away
5.9 Step Nine – Assemble FOSC housing
5.9.1 Put the FOSC cover on the FOSC bottom directly.
5.9.2 Insert locating bolt of FOSC and tighten it with the special wrench.
Important issues: cleaning the housing and pay attention to the above sequence.
6. Fiber Optic Splice Closures (FOSC) inspecting and testing items
Inspecting item |
Technical Requirements |
Inspecting type |
|
Routine test (Before leaving factory) |
Type test |
||
Package |
Each small package contains one fiber optic splice closure, together with its accessories, tools, installation manual and packing list. |
full |
At least 3 sets sampled each time
|
Appearance |
Intact in shape, no burrs, bubbles, chaps, pores, warps, impurities and other defects, all background colors should be even and continual. |
||
Sign |
There is a clear sign on the housing, such as name and model of the product, etc. |
||
Fiber storage device |
The fibers reserved are to be winded in fiber optic splice tray (FOST), the length of fibers housed in FOST is >1.6m, the curved radius is >30mm. During the installation and maintenance, there should be no attenuation on fibers. |
At least 3 sets sampled each time
|
|
Electrical jointing device |
Inside FOSC: metallic components of fiber cables has the functions of electrical putting through, earthing connection and disconnecting. It is possible to install earthing deriving device outside the housing |
||
Sealing performance |
After sealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. |
||
Re-sealing performance |
After reopening and resealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. |
||
Pull |
Bearing pull is ≧ 800N at axle orientation, there should be no breakage on the housing. |
||
Punching |
Bearing pressure of 2000N/10cm for 1 minutes, there should be no breakage on the housing |
||
Impact |
Bearing impact energy of 16N•m, 3 times of impacts there should be not breakage on the housing |
||
Bending |
The spot between the FOSC and seal fitting can bear bending tension of 150N at bending angle of ±450 for 10 circles, there should be no breakage on the housing |
At least 3 sets sampled each time
|
At least 3 sets sampled each time
|
Torsion |
Bearing torsion 50N•m, 10 circle at torsion angle±900, There should be no breakage on the housing. |
||
Temperature circle |
Injected air pressure of 60KPa±5 KPa, the temperature circle ranging from -40℃~+65℃, 10 times of the circular tests (one circular consists of high temperature for 2 hours + indoor temperature for 2 hours + low temperature for 2 hours + indoor temperature for 2 hours ) when the pressure declines, the amplitude is ≦5Kpa, immerse the swatch in clean water of normal temperature for 15 minutes, there should be no air bubbles. |
||
Voltage resistance strength |
After sealing the FOSC according to the stipulated operation procedures, immerse it in clean water of normal temperature in 1.5m depth for 24 hours, there should be no breakdown or arc over between the metallic components of the FOSC, between metallic components and the ground at DC 15KV for 1 minutes. |
||
Isolating resistance |
After sealing the FOSC according to stipulated operation procedure, immerse it in clean water in 1.5m depth for 24h, the isolating resistance between the metallic components of the FOSC, between the metallic components and the ground should be ≧ 2×104MΩ. |